XRNT (XDR20) -40.5 High-Voltage Current-Limiting Fuse for The Wind Power Transformer Protection
XRNT (XDR20) -40.5 High-Voltage Current-Limiting Fuse for The Wind Power Transformer Protection
XRNT (XDR20) -40.5 High-Voltage Current-Limiting Fuse is the ultimate solution for wind power transformer protection. As a factory, we offer top-quality products that guarantee maximum efficiency and safety. Get the best of protection for your transformer with XRNT (XDR20) -40.5 High-Voltage Current-Limiting Fuse now!
Product Detail: XRNT(XDR20)-40.5 High-voltage current-limiting fuse for the wind power transformer protection, applied to ac 50 Hz, rated voltage 40.5 KV power system. As a power transformer and other electric equipment overload and short circuit protection component, mainly installed on the American box change, can box with other electrical components. When the current exceeds a predetermined value after a certain period of time, with its own heat to melt melting breaking circuit switching devices. Construction: The fuse consist of a fuse- link, base and fuse holder (handle), plug-in structure. The fuse-link is cylindrical shape. It is composed of glass fiber epoxy fusion tube, contact round cap, the melt of skeleton, mica, quartz sand.Both ends of the fuse-link insert the contact column of the fuse holder, fixed with set screws and united as one piece. The base semicircle groove put O type sealing ring, plug in fuse holder which install fuse-link to base,screw on cap, insert and hold. Fuse installation dimensions and the dimensions: 1. Fuse-link dimensions see figure 1. Fuse installation dimensions and the dimensions as shown in figure 2. Figure 2. Fuse dimensions and the installation dimensions Fuse holder (base) installation method: 1. remove cap and handle, screw cap on the holder (prevent holder thread damaged). 2. put sealed trap in the corresponding slot, through holder smaller end into housing corresponding holes(user design insulation stents and accessories according to the housing, then should set insulation bracket at first, after to support holder), four holes in holder should mat corresponding bolt, tighten and fixed nut. 3. Move two adjustable block piece on both ends to block slope and keep contact with holder surface, tighten block and retaining bolt. 4. tighten the insulated cable tie (or use 44 - 5U shaped metal wire) to fix holder and insulation bracket, avoid the holder harm by form.