Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10)

We are a factory providing the Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10). Our product ensures reliable performance and easy installation. Contact us for high-quality products.

Request a Quote
  • Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10)
  • Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10)
  • Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10)

PRODUCTS DETAILS

Oil Immersed Load Break Switch

With the transformer oil as insulation and arc extinction medium and energy storing spring operating mechanism, this two-position oil immersed load switch applies to the combined transformer with 50Hz frequency and 25kV rated voltage, it is capable to turn on and off the load current. Equipped with ON and OFF two positions, the clockwise turn is "ON", while anticlockwise is "OFF", the rotation angle should be controlled within 90°. In addition, it can be suitable for end power distribution system or ring-network power distribution system if equipped extra configurations. Main technical parameters Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10)
Overall dimension  Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10) Reservation installation size for transformer housing  Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10) Load switch installation Before installation, please check whether the switching motion is flexible and accurate carefully, only after confirmed to be under good condition, the installation can be implemented, in addition, the load switch must be dried under 65±5ºCcondition by 24h. Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10)Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10)Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10) 5) After installation and connection, it is suggested to carry out "open" and "close" operation to check if the switch can be moved flexibly and if the position indication is correct, if any abnormal, please check the installation of switch and the connection of busbar according to article 2 and 4. Points for attention   1) This load switch can be used to open or close rated current only, while the application for closing and opening the failure current. If over rated current, forbidden to operate switch. 2) Only the special insulated operating arm can be used to operate this load switch to ensure personal safety.   Connection Diagram  Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10)

Hot Products

15kV 200A Rotatable Feedthru Insert

15kV 200A Rotatable Feedthru Insert

15kV 200A Bushing Insert

15kV 200A Bushing Insert

High-Voltage Current-Limiting Fuse for Power Transformer Full Range Protection

High-Voltage Current-Limiting Fuse for Power Transformer Full Range Protection

Deadbreak Type Junction

Deadbreak Type Junction

1kv Silicone Rubber Four Core Cold Shrink Cable Middle Joint

1kv Silicone Rubber Four Core Cold Shrink Cable Middle Joint

HV Dropout Fuse Cutout AH-26

HV Dropout Fuse Cutout AH-26

monitor for lightning arrester

monitor for lightning arrester

12kV24kV 630A Dead break Type H Junction

12kV24kV 630A Dead break Type H Junction

Incoming operating mechanism for gas insulated switchgear

Incoming operating mechanism for gas insulated switchgear

Contact Box Ah3-12kv 180 1250A

Contact Box Ah3-12kv 180 1250A

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours